Sample calculations for Product Flow, Total Flow, & Recovery Rate Percentage:

 

 

Compare your calculation with your expected values. Recovery Rate below minimum percentage is indicative of an internal leak within the Clark Pump.

 

MINIMUM ACCEPTABLE RECOVERY RATE VALUES:

7% Clark Pump (Ventura 150)

6.5% Actual Recovery ---> 5.5% Minimum Acceptable

10% Clark Pump (Ventura 200, Cape Horn, Catalina, Newport 400)

9.0% Actual Recovery ---> 8.0% Minimum Acceptable

20% Clark Pump (Newport 700/1000)

18.5% Actual Recovery ---> 17.5% Minimum Acceptable